Mosa Generator GE 8000 HBT / BBT

Art.-No.:
BEPCK2N7010-/Mosa_config
Only %1 left
Deliverytime
on request
As low as €1,878.49 €1,552.47 Regular Price €2,171.95
Surcharge for delivery Netherlands: 90,00 €
Overview

MOSA Generator GE 8000 HBT / BBT
Complete protective frame, open - Engine shutdown in case of low oil - Engine with fuel tank and silencer - Compund generator

MOSA Generator GE 8000 HBT / BBT

  • Complete protective frame, open
  • Engine shutdown in case of low oil
  • Generator with compound
  • Circuit breaker
  • Thermal circuit breaker for 16A socket
  • LED voltmeter
  • According to EU directives
  • Stage 5 engine according to EU Directive EU 1628-2016

GE 8000 HBT

Item number: CK2N7010

Sockets:

  • Schuko: 1x400V 16A 3P+N+T CEE - 1x230V 16A 2P+T SCHUKO

Optional: Ground fault circuit interrupter/operating hours counter (item number: CK2N7010RY)

Technical data

  • Air cooled
  • Pull starter
Engine HONDA GX390 (Stage 5)
Generator LINZ synchronous three-phase
Generator LINZ synchronous three-phase
Frequency 50 Hz
Fuel unleaded gasoline
PRP single-phase power 4 kVA (3.6 kW) 230 V / 17.4 A
Stand-by three-phase power 8 kVA (6.4 kW) 400 V / 11.5 A
PRP three-phase power 7 kVA (5.6 kW) 400 V / 10.1 A
Tank capacity Lit 6.1
Fuel burn (75% PRP) 2.4 lt/h
Sound pressure LpA 71 dB(A) @ 7m

GE 8000 BBT

Item number: CK1Q5000

Sockets:

  • 1x400V 16A 3P+N +T CEE; 1x230V 16A 2P+T CEE

Optional:

  • RCD/operating hours counter + Schuko socket: 1x400V 16A 3P+N+T CEE - 1x230V 16A 2P+T SCHUKO (item number: CK2Q5010RY)

Technical data

  • Air cooled
  • Pull starter
Motor B&S XR2100 (Stage 5)
Generator LINZ synchronous three-phase
Frequency 50 Hz
Fuel unleaded gasoline
PRP single-phase power 4 kVA (3.6 kW) 230 V / 17.4 A
Stand-by three-phase power 8 kVA (6.4 kW) 400 V / 11.5 A
PRP three-phase power 7 kVA (5.6 kW) 400 V / 10.1 A
Dry weight Kg 80
Tank capacity Lit 6.6
Fuel consumption (75% PRP) 2.7 lt/h
Sound pressure LpA 74 dB(A) @ 7m

Unbalanced load:

For generators with three-phase power (400V), one third of the three-phase power is available for each phase. (for example: 6 kVA with three phases corresponds to 2 kVA per phase ).

When connecting to the house supply (emergency power), the electrician should ensure that all three phases are equally loaded to use the full power.

The Mosa IP 54 generators have 3 reinforced phases, which bring 50% more power to the single phase. (e.g. 12KVA-400V = 4KVA /phase + 50% ≙ 6KVA to one phase).

But beware. The total power of the generator must not be exceeded!


One unit of quantity is equal to 1 piece!
Pictures may contain optional Accessories.
The pictures shown are for reference only, the actual product may differ.

More Information
Deliverytimeon request
HerstellerFerrari Mosa
HerstellerartikelnummerCK2N7010
EAN
Zuschlag für Lieferung nach Österreich (netto)€90.00
Zuschlag für Lieferung in die Schweiz (netto)€270.00
Zuschlag für Lieferung nach Niederlande (netto)€90.00
Sperrgutzuschlag (netto)
Surcharge for delivery Italy€135.00
Zuschlag für Lieferung nach Polen (netto)€135.00
Zuschlag für Lieferung nach Dänemark (netto)€135.00
Zuschlag für Lieferung nach Finnland (netto)€135.00
Zuschlag für Lieferung nach Norwegen (netto)€270.00
Zuschlag für Lieferung nach Schweden (netto)€135.00
Technical Data
Drive mode
Starting system
Rated voltage [V]
Number of sockets 230V
Number of sockets 400V
Continuous power 230V [kVA]
Continuous power 400V [kVA]
AVRNo
InverterNo
Tank capacity [l]
Sound pressure level LPA (7 m) [db(A)]
Sound power level LWA [db(A)
Width [mm]
Height [mm]
Length [mm]
Gewicht [kg]0,00
Energieeffizienzklasse
We found other products you might like!