MOSA Generator GE 8000 HBT / BBT
Complete protective frame, open - Engine shutdown in case of low oil - Engine with fuel tank and silencer - Compund generator
MOSA Generator GE 8000 HBT / BBT
- Complete protective frame, open
- Engine shutdown in case of low oil
- Generator with compound
- Circuit breaker
- Thermal circuit breaker for 16A socket
- LED voltmeter
- According to EU directives
- Stage 5 engine according to EU Directive EU 1628-2016
GE 8000 HBT
Item number: CK2N7010
Sockets:
- Schuko: 1x400V 16A 3P+N+T CEE - 1x230V 16A 2P+T SCHUKO
Optional: Ground fault circuit interrupter/operating hours counter (item number: CK2N7010RY)
Technical data
- Air cooled
- Pull starter
Engine | HONDA GX390 (Stage 5) |
Generator | LINZ synchronous three-phase |
Generator | LINZ synchronous three-phase |
Frequency | 50 Hz |
Fuel | unleaded gasoline |
PRP single-phase power | 4 kVA (3.6 kW) 230 V / 17.4 A |
Stand-by three-phase power | 8 kVA (6.4 kW) 400 V / 11.5 A |
PRP three-phase power | 7 kVA (5.6 kW) 400 V / 10.1 A |
Tank capacity Lit | 6.1 |
Fuel burn (75% PRP) | 2.4 lt/h |
Sound pressure LpA | 71 dB(A) @ 7m |
GE 8000 BBT
Item number: CK1Q5000
Sockets:
- 1x400V 16A 3P+N +T CEE; 1x230V 16A 2P+T CEE
Optional:
- RCD/operating hours counter + Schuko socket: 1x400V 16A 3P+N+T CEE - 1x230V 16A 2P+T SCHUKO (item number: CK2Q5010RY)
Technical data
- Air cooled
- Pull starter
Motor | B&S XR2100 (Stage 5) |
Generator | LINZ synchronous three-phase |
Frequency | 50 Hz |
Fuel | unleaded gasoline |
PRP single-phase power | 4 kVA (3.6 kW) 230 V / 17.4 A |
Stand-by three-phase power | 8 kVA (6.4 kW) 400 V / 11.5 A |
PRP three-phase power | 7 kVA (5.6 kW) 400 V / 10.1 A |
Dry weight Kg | 80 |
Tank capacity Lit | 6.6 |
Fuel consumption (75% PRP) | 2.7 lt/h |
Sound pressure LpA | 74 dB(A) @ 7m |
Unbalanced load:
For generators with three-phase power (400V), one third of the three-phase power is available for each phase. (for example: 6 kVA with three phases corresponds to 2 kVA per phase ).
When connecting to the house supply (emergency power), the electrician should ensure that all three phases are equally loaded to use the full power.
The Mosa IP 54 generators have 3 reinforced phases, which bring 50% more power to the single phase. (e.g. 12KVA-400V = 4KVA /phase + 50% ≙ 6KVA to one phase).
But beware. The total power of the generator must not be exceeded!
One unit of quantity is equal to 1 piece!
Pictures may contain optional Accessories.
The pictures shown are for reference only, the actual product may differ.
Deliverytime | on request |
---|---|
Hersteller | Ferrari Mosa |
Herstellerartikelnummer | CK2N7010 |
EAN | |
Zuschlag für Lieferung nach Österreich (netto) | €90.00 |
Zuschlag für Lieferung in die Schweiz (netto) | €270.00 |
Zuschlag für Lieferung nach Niederlande (netto) | €90.00 |
Sperrgutzuschlag (netto) | |
Surcharge for delivery Italy | €135.00 |
Zuschlag für Lieferung nach Polen (netto) | €135.00 |
Zuschlag für Lieferung nach Dänemark (netto) | €135.00 |
Zuschlag für Lieferung nach Finnland (netto) | €135.00 |
Zuschlag für Lieferung nach Norwegen (netto) | €270.00 |
Zuschlag für Lieferung nach Schweden (netto) | €135.00 |
Drive mode | |
---|---|
Starting system | |
Rated voltage [V] | |
Number of sockets 230V | |
Number of sockets 400V | |
Continuous power 230V [kVA] | |
Continuous power 400V [kVA] | |
AVR | No |
Inverter | No |
Tank capacity [l] | |
Sound pressure level LPA (7 m) [db(A)] | |
Sound power level LWA [db(A) | |
Width [mm] | |
Height [mm] | |
Length [mm] | |
Gewicht [kg] | 0,00 |
Energieeffizienzklasse |