Mosa Generator GE S-7554 YDT Series
- Yanmar, diesel engine, air cooled, E-Start
- engine - stop oil shortage
- 3~ synchronous generator, "IP 54
- Electronic voltage regulator
- Brushless
- Insulation monitoring or according to DGUV-B
- Automatic circuit breaker
- Tank indicator
Mosa Generator GE S-7554 YDT, with RCD and AVR
Item number: CK5P80U2
Diesel genset YANMAR L 100 V - three-phase synchronous generator
With RCD and AVR (automatic voltage regulator)
TECHNICAL DATA
Engine |
Type |
Yanmar L100V |
Fuel |
DIesel |
Starter motor |
Reserving or electric starter |
Maximum power mains Stand By |
6.4 kWm (8.5 hp) |
Maximum power mains PRP |
5.7 kWm (7.7 HP) |
Cylinder / displacement |
1 / 435 cm³ |
Speed |
3000 rpm |
Cooled |
Air |
Nominal output power |
|
Power three-phase stand-by |
7 kVA (5.6 kW) /400V/ 10A |
Power three-phase PRP |
6 kVA (4.8 kW) /400V/ 8.7A |
Power single-phase PRP |
5 kVA/kW /230V/ 21.7A |
Frequency |
50 Hz |
General data |
|
Tank capacity |
20 lt. |
Running time (75% of PRP) |
20 h |
Sound level value Lwa (pressure LpA) |
99 dB(A) (74 dB(A) @ 7m) |
Dry weight |
141 kg |
Dimensions (LxWxH) |
770x520x650 mm |
Sliding load:
For generators with three-phase current (400V), one third of the three-phase power is available for each phase. (for example: 6 kVA with three phases corresponds to 2 kVA per phase ).
When connecting to the house supply (emergency power), the electrician should ensure that all three phases are equally loaded to use the full power.
The Mosa IP 54 generators have 3 reinforced phases, which provide 50% more power to the single phase. (e.g. 12KVA-400V = 4KVA /phase + 50% ≙ 6KVA to one phase).
But beware. The total power of the generator must not be exceeded!
Mosa Generator GE S-7554 YDT, with Isometer and AVR
Item number: CK5P80T2
Diesel genset YANMAR L 100 V - three-phase synchronous generator
With isometer and AVR (automatic voltage regulator)
TECHNICAL DATA
Engine |
Type |
Yanmar L100V |
Fuel |
DIesel |
Starter motor |
Reserving or electric starter |
Maximum power mains Stand By |
6.4 kWm (8.5 hp) |
Maximum power mains PRP |
5.7 kWm (7.7 HP) |
Cylinder / displacement |
1 / 435 cm³ |
Speed |
3000 rpm |
Cooled |
Air |
Nominal output power |
|
Power three-phase stand-by |
7 kVA (5.6 kW) /400V/ 10A |
Power three-phase PRP |
6 kVA (4.8 kW) /400V/ 8.7A |
Power single-phase PRP |
5 kVA/kW /230V/ 21.7A |
Frequency |
50 Hz |
General data |
|
Tank capacity |
20 lt. |
Running time (75% of PRP) |
20 h |
Sound level value Lwa (pressure LpA) |
99 dB(A) (74 dB(A) @ 7m) |
Dry weight |
141 kg |
Dimensions (LxWxH) |
770x520x650 mm |
Sliding load:
For generators with three-phase current (400V), one third of the three-phase current power is available for each phase. (for example: 6 kVA with three phases corresponds to 2 kVA per phase ).
When connecting to the house supply (emergency power), the electrician should ensure that all three phases are equally loaded to use the full power.
The Mosa IP 54 generators have 3 reinforced phases, which bring 50% more power to the single phase. (e.g. 12KVA-400V = 4KVA /phase + 50% ≙ 6KVA to one phase).
But beware. The total power of the generator must not be exceeded!